2024-02-MKP-카탈로그28p-영문_수정2(저)
15 VIC-S220 | VIC-W220 Description VIC-W220 Flow Range (N 2 Equivalent) 5 sccm ~ 50 slm Flow Control Range 2 ~ 100% of Full Scale Accuracy ≤ ± 1% of Full Scale Response Time ≤ 1 sec Linearity ≤ ± 0.2% of Full Scale Repeatability ≤ ± 0.2% of Full Scale Value Type Normal Closed Solenoid Seal Type Metal + Teflon Capsule O-ring Input / Output Signal Analog Mode: 0 ~ 5VDC or 4 ~ 20mA Digital Mode: RS-485 (D-NET Possible) Power Supply +24VDC (+15VDC products are also available.) Recommended Operating Temperature Range 15 ~ 35℃ Warm-up Time 30 min Electrical Connection D-SUB 9PIN MALE Weight (STS) 0.97 kg Product Specification ※ ‘sccm’ and ‘slm’ is the flow unit at the standard condition (0℃, 101.3 kPa). ※ This specification is subject to change without prior notice. ▪Specialized for toxic and corrosive gases by applying metal gasket and Teflon capsule O-ring ▪Reinforce the external leak standard through in/out fitting welding ▪Applied the surge protection circuit to reinforce the safety standard ▪Applied the temperature compensation circuit to maintain the accuracy against the environmental temperature change Product Description VIC-W220 Digital Mass Flow Controller VIC-W220 Exterior Drawing Model A 1/4" VCR 1/2" VCR VIC-W220 130.6 137.4 76 48 2-M4 DP:5 VCR A 12.7 30.6 20 137.3