2024-02-MKP-카탈로그28p-영문_수정2(저)
EXO-U100 Series Digital Mass Flow Controller ▪Acquired the explosion proof certification (Certification code Ex-Code : Ex nA IIC T4) ▪Designed the double-disc valve - Enable to control large flow with low pressure - Compact product size ▪Robust design used in pilot and production plant (IP65) ▪Applied surge protection circuit to reinforce the safety standard ▪Applied the temperature compensation circuit to maintain the accuracy against the temperature change Product Description Ballast Water Treatment System Sewage treatment plant Oil refinery Vehicle charging station/gas station Fuel/gas tank Gas pipeline and station Chemical treatment plant Surface treatment industry ▪As an autonomous certification system to maintain safety level fit to the electronic devices used under the environment having risk of explosion and to prevent the overlapped certification, it is one of the IEC conformity evaluation systems. ▪The aim is to provide the safety level required for the equipment and services used in the explosive environment. And it is composed of equipment certification, service facility certification, conformity mark license and personal authentication system. ▪The target items include the explosion-proof devices applied to the fields that can cause the atmospheric explosion by the inflammable gas, vapor, dust, etc. (Zone 2) What is the explosion-proof certification? Target Items